| Sector | abcCivil Works | Tender Value | INR 16.13 Crore approx. | Location | Punjab - India | Ref.No | 86708941 | Closing Date | 01 - Sep - 2025 | | | Construction of Critical Care Block (g+storey) in Civil Hospital at Mansa (punjab) , 2.0 , a) Civil Work A1) Construction of Critical Care Block (g+4 Storey) with a Provision of Foundation (g+4 Storey) Earth Work in Excavation in Foundations, Trenches Etc. in All Kinds of Soil Where Pick Jumper Work is Not Involved and Not Exceeding 2.0 Metres Depth Including Dressing of Bottom and Sides of Trenches, Stacking the Excavated Soil Clear From the Edge of Excavation and Subsequent Filling Around Masonry in 15 Cm. Layers with Compaction Including Disposal of All Surplus Soil as Directed Within a Lead of 30 Metres. , providing and Applying Anti Termite Treatment Using Pre Constructional Chemical Treatment Measures as Per is - 6313 - 2001 ( Part 2 ) & Using Chemical Containg Chloropyrifos Systemic Insecticide Diluted to Manufacturer's Specifications (i) in Foundation Pits, By Treating the Bottom & Sides Upto Height of 300mm By Uniformly Spraying Solution @ 5 Litre / Sqm (ii) in the Refill Earth on Both Sides of All Built Up Walls @ 7.5 Litre / Running Meter ( Width - 300 Mm, Depth - 450 Mm ) (iii) Before Laying the Floor, By Uniformly Sprinkling the Top Surface of the Consolidated Earth Within the Outer Perimeter @ 5 Litre Solution Per Sqm. , reinforced Cement Concrete M-25 Mechanicaly Batch Mixed Using Batch Type Concrete Mixer as Per Is1791 and Vibrated By Needle Vibrator But Excluding Steel Reinforcement Centring and Shuttering in Foundation and Plinth. , cement Concrete 148 with Stone Aggregate 40mm Gauge. Mixing By Mechanical Means Using Concrete Mixer Volumetric Type , shuttering for Faces of Concrete Foundations and Foundation Beam & Plinth Beam (vertical Or Battering) , first Class Burnt Brick Work Laid in Cement Sand Mortar 16 in Foundation and Plinth. , damp Proof Course 4cm Thick of Cement Concrete 124 with Water Proofing Compound as Per Manufacture Guidelines. , reinforced Cement Concrete M-20 Mechanicaly Batch Mixed Using Batch Type Concrete Mixer as Per Is1791 and Vibrated By Needle Vibrator But Excluding Steel Reinforcement Centring and Shuttering in Supersturcture. door Lintels , extra Rate for First Floor , extra Rate for Second Floor , extra Rate for Third Floor , extra Rate for Fourth Floor , extra Rate for Fifth Floor , shelves Total All Floor , reinforced Cement Concrete M-25 Mechanicaly Batch Mixed Using Batch Type Concrete Mixer as Per Is1791 and Vibrated By Needle Vibrator But Excluding Steel Reinforcement Centring and Shuttering in Supersturcture. |
|
|
If you are a new user, then please
register, it's Free and then fill the form below.
If you are registered with us, just fill the form below, we will get back to you
shortly.
|
All fileds marked with '*' are compulsary.
|
|
|