| | Sector | abcSecurity Services | Tender Value | 30.29 Lakhs approx. | | Location | Rajasthan - India | Ref.No | 97383992 | | Closing Date | 04 - Jul - 2026 | | | | Provision of annual maintenance services for various air conditioning systems including 1.5T, 2.0T, and 8.5T units, as well as VRV and VRF systems. The scope includes routine and breakdown maintenance, replacement of components such as capacitors, motors, coils, and compressors, and ensuring the systems are operational with necessary refrigerants. Labour Charges for Service and maintenance of 1.5T and 2.0T AC, Labour Charges for Routine or Breakdown Service and maintenance of 8.5T AC, Labour Charges for Service and maintenance of VRV and VRF, Labour Charges for Service and maintenance of Air Washer ventilators and Scrubbers, chemical and other items required for Servicing of AC, VRV and VRFs, Topping up with suitable cooling gas of refrigerant in AC, VRV and VRF units, Replacement of Running capacitor 36 mfd, 240 V of 1.5T, 2.0T and 8.5T AC, Replacement of Running capacitor 45 to 50 mfd, 240 V of 1.5T, 2.0T and 8.5T AC, Replacement of Motor capacitor 2.5 mfd, 240 V of 1.5T, 2.0T and 8.5T AC, Replacement of Motor capacitor 4 mfd, 240 V of 1.5T, 2.0T and 8.5T AC, Replacement of Indoor Fan Motor of 1.5T, 2.0T and 8.5T AC, Replacement of Outdoor Fan Motor of 1.5T, 2.0T and 8.5T AC, Replacement of Condenser Coil of 1.5T, 2.0T and 8.5T AC, Replacement of Cooling Coil of 1.5T, 2.0T and 8.5T AC, Supplying and Replacement of PCB For 1.5TR and 2.0 TR inverter AC, Supplying and Replacement of PCB For 8.5 TR AC, Repairing of PCB For 1.5TR and 2.0 TR inverter AC, Repairing of PCB For 8.5 TR inverter AC, Replacement of old burnt or defective compressor 1.5 TR AC Compressor, Replacement of old burnt or defective compressor 2 TR AC Compressor, Replacement of old burnt or defective compressor 8.5 TR AC Compressor, Replacement of Magnet Switch for VRV and VRF, Replacement of Motor capacitor 2-5 mfd, 240 V for VRV and VRF, Replacement of Motor capacitor 4 mfd, 240 V for VRV and VRF, Replacement of Outdoor Fan Motor for VRV and VRF, Replacement of Condenser Coil for VRV and VRF, Replacement of Cooling Coil for VRV and VRF, Replacement of old burnt compressor for Hot and cold type VRV and VRF, Repairing of 8 to 12.5 HP Monoblock pumps, Repairing of 1 to 2 HP Monoblock pumps, Repairing and Re-installation of Starters for various pumps in air ventilators, Replacement of old burnt Starters for various pumps in air ventilators, Replacement of old burnt connectors and Contactors for pumps |
|
|
If you are a new user, then please
register, it's Free and then fill the form below.
If you are registered with us, just fill the form below, we will get back to you
shortly.
|
All fileds marked with '*' are compulsary.
|
|
|
|