Sort By :
3 Tenders

Live Compressor online Tenders in India. Get all the latest Compressor Tender Document. Compressor Tender Corrigendum and News from all the Government Dept and Private Company across India

1
Sector Crude Oil / Natural Gas / Mineral Fuels Tenders Tender Value N.A.
Location Maharashtra Tenders Ref.No 77530138
Closing Date 18 - Nov - 2024  |  17 Days to go View Tender Details
Supply of LT Electrical Motor Three Phase, 5.6 kW (PGC GG LO/HO pump ICG-1), LT Electrical Motor Three Phase, 125 kW (CHU Compressor ICG-2), LT Electrical Motor Three Phase, 7.5 kW (Chiller water pump ICG-3), LT Electrical Motor Three Phase, 7.5 kW (PGC Shelter Fan ICG-4), LT Electrical Motor Three Phase, 30 kW (PGC Seal Oil Pump ICG-5), LT Electrical Motor Three Phase, 30 kW (PGC L/O Oil Pump ICG-6), LT Electrical Motor Three Phase, 30 kW (PGC Gas Cooler 1st&2nd Stage ICG-10), LT Electrical Motor Three Phase, 2 HP (STP macerator ICG-11), LT Electrical Motor Three Phase, 5.5 kW (TG GG LO/HO pump ICP-3), LT Electrical Motor Three Phase, 132 kW (Hot Oil Circulation Pump ICP-5), LT Electrical Motor Three Phase, 45 kW (Hot Oil Circulation Pump ICP-6), LT Electrical Motor Three Phase, 22 kW (TG PT AC LO ICP-8), LT Electrical Motor Three Phase, 0.75 kW (OCI ICP-10), LT Electrical Motor Three Phase, 1 HP (STP macerator ICP-11), LT Electrical Motor Three Phase, 30 kW (UG radiator fan ICW-1), LT Electrical Motor Three Phase, 0.75 HP (UG AC lube oil pump ICW-2), LT Electrical Motor Three Phase, 132 kW (Vacuum Pump ICW-3), LT Electrical Motor Three Phase, 2.2 kW (IA-UA Compressor cooling fan ICW-4), LT Electrical Motor Three Phase, 7.5 kW (HVAC Chilled Water Pump ICW-5), LT Electrical Motor Three Phase, 7.5 kW (HVAC condensor Fan ICW-7), LT Electrical Motor Three Phase, 132 kW (IA-UA Compressor ICW-8), LT Electrical Motor Three Phase, 15 kW (GTG AC lube oil pump ICPR-2), LT Electrical Motor Three Phase, 93.2 kW (PGC starter ICPR-4), LT Electrical Motor Three Phase, 11.2 kW (PGC pre-post lube oil pump ICPR-5), LT Electrical Motor Three Phase, 11 kW (GTG air blast lube oil cooler fan ICPR-6), LT Electrical Motor Three Phase, 15 kW (PGC 1st stage gas cooler ICPR-7), LT Electrical Motor Three Phase, 37 kW (PGC 2nd stage gas cooler ICPR-8), LT Electrical Motor Three Phase, 30 kW, (PGC 3rd stage gas cooler ICPR-9), LT Electrical Motor Three Phase, 11 kW (PGC oil cooler ICPR-10), LT Electrical Motor Three Phase, 0.37 kW (Chemical injection pump ICPR-12), LT Electrical Motor Three Phase, 160 kW (IA-UA Compressor ICPR-13), LT Electrical Motor Three Phase, 1.5 kW (SHW MIP Lube Oil Cooler Fan SHP-46), LT Electrical Motor Three Phase, 150 kW (SHG Compressor SHP-47), LT Electrical Motor Three Phase, 3 kW (SHP AIR Compressor LO COOLER FAN SHP-49), LT Electrical Motor Three Phase, 185 kW (SHP I/U AIR Compressor SHP-50), LT Electrical Motor Three Phase, 3 kW (Lube Oil Pump of MOL-350/360 BHS-1), LT Electrical Motor Three Phase, 0.55 kW (Lube Oil Cooler Fan of MOL-350/360 BHS-2), LT Electrical Motor Three Phase, 5.5 kW (cooling water pump P-915/925 BHS-3), LT Electrical Motor Three Phase, 132 kW (Hot Oil Circulation Pump P-1760/P-1770 BHS-4), LT Electrical Motor Three Phase, 45 kW (Glycol Recirculation Pump P-880/890/980/990 BHS-9), LT Electrical Motor Three Phase, 5.5 kW (Glycol Booster Pump P-875/885/985/995 BHS-10), LT Electrical Motor Three Phase, 132 kW (SA CTP P-750/755/760 BHS-11), LT Electrical Motor Three Phase, 110 kW (TVF of SLQ TGs BHS-12), LT Electrical Motor Three Phase, 110kW (TVF of SLQ TGs BHS-13), LT Electrical Motor Three Phase, 75 kW (GVF of SLQ TGs BHS-14), LT Electrical Motor Three Phase, 0.66 kW (Generator Lube Oil Cooler Fan of SLQ TG BHS-16), LT Electrical Motor Three Phase, 3.3 kW (Generator AC Lube Oil Pump of SLQ TG BHS-17), LT Electrical Motor Three Phase, 1.5 kW (Mist Evacuator of SLQ TG BHS-18), LT Electrical Motor Three Phase, 5.5 kW (Supply Fan of Transformers BHS-24), LT Electrical Motor Three Phase, 4 kW (Exhaust Fan of Transformers BHS-25), LT Electrical Motor Three Phase, 11 kW (Combined Cooler Fan of PGC BHS-28), LT Electrical Motor Three Phase, 22 kW (Gas Cooler Fans of PGC BHS-29), LT Electrical Motor Three Phase, 7.5 kW (GG LO/HO Pump of PGC BHS-31), LT Electrical Motor Three Phase, 45 kW (lube oil pump of PGC BHS-33), LT Electrical Motor Three Phase, 30 kW (PGC Lube Oil Pump NQP-3), LT Electrical Motor Three Phase, 75 kW (PGC Seal Oil Pump NQP-4), LT Electrical Motor Three Phase, 7.5 kW (PGC-C GG Lube Oil Pump NQG-10), LT Electrical Motor Three Phase, 132 kW (Utility Air Compressor NQO-18), LT Electrical Motor Three Phase, 5.5 kW (TG-1 Gas Generator Lub/hyd Oil Pump WIN-1), LT Electrical Motor Three Phase, 3.7 kW (MIP Lube Oil WIN-7), LT Electrical Motor Three Phase, 3.7 kW (MIP Air Blast Cooler WIN-8), LT Electrical Motor Three Phase, 4 kW (Starting Air Compressor-UG WIN-11), LT Electrical Motor Three Phase, 4 kW (UG Enclosure air inlet Fan WIN-12), LT Electrical Motor Three Phase, 0.55 kW (AC Lube Oil-UG WIN-13), LT Electrical Motor Three Phase, 12.6 kW (Radiator Fan UG WIN-14), LT Electrical Motor Three Phase, 11kW (UG Cooling Water Pump WIN-15), LT Electrical Motor Three Phase, 1.5 kW (Instrument Air Compressor Lube Oil Pump WIN-17), LT Electrical Motor Three Phase, 5.5 kW (Water Maker Cleaning Pump WIN-18), LT Electrical Motor Three Phase, 18.5 kW (Water Maker High Pressure Pump WIN-19),
2
Sector Security Services Tenders Tender Value N.A.
Location Assam Tenders Ref.No 77480182
Closing Date 14 - Nov - 2024  |  13 Days to go View Tender Details
Supply of AC Compressor, AC CAPACITOR, GAS REFILLING, CHEMICAL SERVICING, SERVICING
Qty:5

3
Sector Municipal Corporations Tenders Tender Value Rs. 2.88 Million approx. / 28.87 Lakh approx.
Location Gujarat Tenders Ref.No 77117236
Closing Date 07 - Nov - 2024  |  6 Days to go View Tender Details
Tender for Operation & Comprehensive Maintenance of Electro-mechanical Instruments & Equipments for Dafnala Children Park at East Side Sabarmati Riverfront for Two (2) Years, Providing of all Man power, labour (Including reliever to ensure presence of specified, type and no. of manpower per shift, as applicable) along with administration &, management charges including running office, cost of Workmen compensation, , Insurance Policy etc. labour for testing, repairing and maintenance of equipments, works for one Month of tender works, For First Year, Electrician (1 No.), Helper (1 No.), For Second Year, Electrician (1 No.), Helper (1 No.), Total of PART A, B Comprehensive Maintenance & Repair:, Comprehensive maintenance (Routine, Preventive & Break down maintenance) and, repairing work charges of all Ele. & Mech. equipments with replacement of spares, , materials, consumables along with administration & management charges including, cost of lubricants, tools, statutory periodical approvals & testing of equipments etc., Providing & erecting Approved make Ceiling Fan with double ball bearing ISI, mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having, blades aluminium body and blade sets having ornamental design shanks, canopy, erected with earthing. [ Make shall be approved by Engineer in Charge], Supplying & erecting single phaseapproved make industrial exhaust fan suitable for, medium duty ring mounted low noise operation suitable for medium duty having, following dia size and maximum speed in RPM, Supplying, erecting, connecting, testing and commissioning of Following type LED, Light Fixture with all necessary Hardware, internal wiring with Lamp, Ballast etc., required accessories complete in all respect, Any kind of LED Light Fixtures (with Basic rate of Rs.1500), Any kind of LED Light Fixtures (with Basic rate of Rs.3500), Any kind of Planter Light / Foot Light / Shrub light complete in all respect with, necessary accessories. (with Basic rate of Rs.6000), Any kind of Ground burial / Tree up light complete in all respect with necessary, accessories, Wiring, Drivers etc. ( with basic rate of Rs.10000/-), Any kind of Post top/Decorative Light Fixtures ( with basic rate of Rs.20000/-), Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity, 150 Ltr per hour @ an ambient temp of 45° C. The outlet temp. of the water should, drop by 15°C within a hour, The water cooler should be comprising of hermetically, sealed Compressor, fan motor, condensing unit, water tank surrounded by evaporating, , coil, thermostats, relay etc. complete with necessary inlet & outlet connection. The, body of water cooler will be made from Stainless Steel., Supplying and erecting water filter cum purifier with ultra violate technology., Aquaguard /waterdoc model or equivalent symphony / crystal / videocon model), Condensor Replacement of watercooler with pressure testing & gas charging, S.I.T.C. of Booster pump for water purifier, S.I.T.C. of New water level sensor for water purifier, S.I.T.C. of Bowl filter set for water purifier, S.I.T.C. of New outdoor unit of Split ac, S.I.T.C. of New indoor unit of Split ac, Outdoor Garden Speaker Taps (70/100), 10/20/40 watts Rating, 2000 Watt Digital Amplifier, 2 core 1.5 Sq.mm Flexible Cable, Supplying & erecting earth pit of minimum bore dia.150mm size approved make, Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made, corrosion free hot dipped G.I. Pipes having Outer pipe dia of 50mm having 80-, Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, , connection terminal dia of 12mm with constant ohmic value surrounded by highly, conductive compound with high charge dissipation suitable for following type of, applications with chamber and heavy duty cover. (approved make OEM has to submit, test certificate) & having back filling compound of (B) Inner chemical (CCM, Compound)- Resistivity:- 0.2 / meter testing as per IEC 62561-2017, Voltage drop:-, 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound:-, Earthing compound should be capable to retain moisture for long time Necessary, a) For Electrical Installation up to 440V in normal soil, Length of pipe - 1 Mtr, Back filling compound - 1 Nos Bag of 15 Kg., b)For Electrical installation up to 11 KV in normal soil., Length of Pipe : 2.00 mtrs, Back filling Compound :1 no. Bag of 25 Kg., c) For Electrical Installation covering Transformer Neutrals, Lightning arrester, Earthing, A.C.Plant & Sensitive Computer System (like Automation, SCADA), independent Earthing in normal soil., Length of Pipe : 3.00 mtrs, Back filling Compound :2 nos Bags of 25 Kg., Supplying & erecting approved make self-priming domestic monoblock water pump, with 1 H.P motor, suitable for operation on 230 volts, 50c/s. AC supply with metallic, flange, and M.S. impeller delivery and following discharge, a) 40 LPM at 24 mtrs. head suitable for 25mm dia. Delivery- C
 Search Within Results
 Login/Register
Members/Visitors Login to continue
 Email Id:
 Password:


 Forgot Password?
 Tenders by Industry
Skip Navigation Links.
Expand Chemicals TendersChemicals Tenders
more  »
Tenders by Ownership
Central Government/Public Sector Tenders
Co-operatives Tenders
Corporations/ Associations/ Others Tenders
Education & Research Institutes Tenders
Joint Sector Tenders
Non classified Tenders
Private Sector Tenders
Research Institutes Tenders
State Government Tenders
Trust Tenders
 Tenders by State in India
Andhra Pradesh Tenders
Delhi Tenders
Gujarat Tenders
Madhya Pradesh Tenders
Maharashtra Tenders
Rajasthan Tenders
Tamil Nadu Tenders
Uttar Pradesh Tenders
West Bengal Tenders
more  »